DX ejectors

Working domains

Suction pressure up to 4000 Pa
Suction flow 20-1000 kg/s
Supply pressure 3 to 7 barg
Kinetic efficiency 13-70 %

Suction pressure[Pa] vs Suction flow[kg/s]

The DX Aerodin Coanda ejectors have 2 main dimensions and also 3 geometric dimensions and 2 other thermodynamic supply parameters (pressure and temperature) in order to control the flow and make the necessary adjustments or each flow conditions and each customers needs.
The Coanda ejector is more complex flow device than a simple rotor fan or blower therefore the flow characteristics is done by adjustments of geometric dimension, pressure and temperature. The input temperature is critical for the efficiency of the device therefore the efficiency is not shown on the diagram because is depending on the input local customer conditions.
The diagram suction pressure [relative Pa] vs suction flow [kg/s] for different "p" supply pressures [barg] should be drawn wherever inside the following domain:

DX

Dimensions & weight

Length min 5000 mm
Duct min 1500 mm
Weight min 250 kg

Note:
AERODIN is reserving the right to update the data according with new theory estimation, design or technology.